		<item>
		<title>By: Eric</title>
		<link>http://www.sun-volt.com/blog/2009/11/09/enphase-m-190-microverters/comment-page-1/#comment-122</link>
		<dc:creator>Eric</dc:creator>
		<pubDate>Mon, 14 Dec 2009 17:15:44 +0000</pubDate>
		<guid isPermaLink="false">http://www.sun-volt.com/blog/?p=465#comment-122</guid>
		<description>Interesting. Seattle City Light has no problem with them. They (and We as installers) like the idea of the inverters automatically shutting down on the roof when grid voltage is down. Of course we install an accessible disconnect for them as well. I&#039;d like to see the testing procedure you come up with.</description>
		<content:encoded><![CDATA[<p>Interesting. Seattle City Light has no problem with them. They (and We as installers) like the idea of the inverters automatically shutting down on the roof when grid voltage is down. Of course we install an accessible disconnect for them as well. I&#8217;d like to see the testing procedure you come up with.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Paul</title>
		<link>http://www.sun-volt.com/blog/2009/11/09/enphase-m-190-microverters/comment-page-1/#comment-121</link>
		<dc:creator>Paul</dc:creator>
		<pubDate>Fri, 11 Dec 2009 22:27:18 +0000</pubDate>
		<guid isPermaLink="false">http://www.sun-volt.com/blog/?p=465#comment-121</guid>
		<description>Hey Eric,

I am working on a 5 KW system this weekend using the M210 inverters with the Sanyo 215N panels.  Should be fun.  One thing that I have run into is the utility company doesn&#039;t like them.  Each time I do a system test and certification, I go round and round with the engineer about leakage current vs. monitoring current.   I am working out a standardized acceptance testing procedure for New York State.</description>
		<content:encoded><![CDATA[<p>Hey Eric,</p>
<p>I am working on a 5 KW system this weekend using the M210 inverters with the Sanyo 215N panels.  Should be fun.  One thing that I have run into is the utility company doesn&#8217;t like them.  Each time I do a system test and certification, I go round and round with the engineer about leakage current vs. monitoring current.   I am working out a standardized acceptance testing procedure for New York State.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Eric</title>
		<link>http://www.sun-volt.com/blog/2009/11/09/enphase-m-190-microverters/comment-page-1/#comment-120</link>
		<dc:creator>Eric</dc:creator>
		<pubDate>Fri, 11 Dec 2009 22:02:08 +0000</pubDate>
		<guid isPermaLink="false">http://www.sun-volt.com/blog/?p=465#comment-120</guid>
		<description>We just installed 8.4 kW of M-190&#039;s, 3kW more this weekend. I like them to an extent:

1. The module-by-module monitoring offered by Enphase is GREAT!
2. The shade-control factors offered by MI&#039;s in general is GREAT!
3. Don&#039;t use these with Clicksys Racking unless you install the sliders for your midclips FIRST! (Jeez we learned that lesson the $hard$ way!!)
4. They make sense financially up to about the 5kW level. Then, the cost ($160 ea) outweighs the benefits of a central inverter in my mind. ($4k for MI&#039;s vs. ~ $3.5k for a central inverter)

All in all, our customers are very stoked on the visual monitoring, and I particularly like the email notifications. Starts the warranty process automatically!!~

Solar Epiphany</description>
		<content:encoded><![CDATA[<p>We just installed 8.4 kW of M-190&#8217;s, 3kW more this weekend. I like them to an extent:</p>
<p>1. The module-by-module monitoring offered by Enphase is GREAT!<br />
2. The shade-control factors offered by MI&#8217;s in general is GREAT!<br />
3. Don&#8217;t use these with Clicksys Racking unless you install the sliders for your midclips FIRST! (Jeez we learned that lesson the $hard$ way!!)<br />
4. They make sense financially up to about the 5kW level. Then, the cost ($160 ea) outweighs the benefits of a central inverter in my mind. ($4k for MI&#8217;s vs. ~ $3.5k for a central inverter)</p>
<p>All in all, our customers are very stoked on the visual monitoring, and I particularly like the email notifications. Starts the warranty process automatically!!~</p>
<p>Solar Epiphany</p>